Starting and Stopping the Generator - EFI Only
Important: Batteries should have a combined voltage between 48V–49.5V before starting.
Starting
- Fuel: Fill the fuel tank.
- Preparation: Press and hold "IDLE".
- Crankshaft: Repeatedly pull the rope in quick succession until combustion initiates.
- Idle: Once idling, allow it to warm up to 60°C.
- Run: Press and hold "RUN"; the throttle should increase.
- Stabilize: Allow it to warm up and balance voltage for approximately 60 seconds.
Stopping
- Cool Down: Stay in "RUN" mode for approximately 60 seconds after a flight.
- Idle: Once the cylinder head temperature reaches 110°C, press and hold "IDLE".
- Final Shutdown: Allow it to cool to 90°C, then press and hold "STOP".
Starting and Stopping the Fuel Cell - Hydrone Only
Important: Batteries should have a combined voltage between 48V–49.5V before starting.
Starting
- Preparation: Fill the hydrogen tank and ensure the "RUN" SD card is inserted.
- Connection: Connect batteries and the hydrogen regulator to the fuel cell.
- Activation: Press and hold the pill-shaped "START" button for approximately 3 seconds.
Stopping
Shutdown: Press and hold the pill-shaped "START" button for approximately 3 seconds.